Discussion ProBrewer Message Board Brewery Operations Boiler Q&A If this is your first visit, be sure to check out the FAQ.You will need to register before you can post. To start viewing messages, select the forum that you want to visit from the selection below.
Read More11/11/2013 · Provided you can do it outside and can manage the waste steam. Just it is not very efficient. I tried it inside and it turned the still room into a sauna. Thermally it is not very efficient as you waste a lot of energy and it is also slow. If you can increase the thermal gradient it works a lot better.
Read More27/2/2021 · Another boiler replacement thread - just want to make sure we're making the right call. We have no boiler currently - house is (badly) heated by an oil stove in the kitchen. Bungalow, 1000sqft, 3 bedrooms. We've been quoted 3.5k for following: - External Firebird
Read MoreTracking Number: 11-701 3.5.x.x Tube Replacement Tubes shall be replaced with like tubes supplied by an ASME certificate holder using certified material (tubes, cement, matching sleeves, fillers.. etc) in accordance with the requirements of the ASME Boiler
Read MoreBG have a vested interest in having you get a new boiler. They know that their fixed price contract is going to become costly for them. Before making a decision to change the boiler get a good local Gas Safe fitter to look it over and ask him about parts availability. I
Read MoreWater Gage Glass Placement Explained • 1. Lowest Permissible Water Level- At which level there will be no danger of overheating (Level A). • 2. Water Connection for Water Column- Must be 1" below low visibility point of gage glass and at least 1" NPT. The line
Read More"Your boiler's manufacturer stopped making your model of boiler a while ago. They also told us that nearly all the replacement parts for your boiler are no longer available. This means that we may not be able to fix your boiler if it breaks down, but we'll do our best to
Read More3/9/2019 · If you liked you could plaster board under the stairs or use non asbestos type board. All the boilers air needs are drawn from without the building - probably unlike your current boiler. You must see that the flue complies fully in it's placement.
Read More14/1/2010 · Hi, We have been quoted €3200 for supply and fit of 50000btu boiler, pump,timer,inhibiter and control pack. I know we can get the grant and it will bring it down to €2500 but still seems steep. Can anyone advise or even reccomend a supplier. We are based in north
Read More9/3/2014 · Go to your local plumbing merchant and ask for the boiler you want.They will probably have a make they promote for a better price. See if they can refer you to one of their plumber customers. Reckon on a day to replace if you do not need any major additional piping done however it may be an opportunity to see if the system can be upgraded to better controls and higher efficiency.
Read More25/6/2012 · Some advice needed. Im going to replace the gas boiler in my house and have had a number of quotes from a plumber, bord gais and airtricity. Airtricty quoted in putting in a Vaillant system boiler, replacement controls, 2 zone controls, cylinder stat, magna cleaner
Read MoreA 1.3 million btu, low pressure cast iron boiler by weil-mcclean, model LGB-11. It has a 5" header with 5X2" T fittings feeding the brewery. The steam main to the kettle in 2" with 5 elbows in line, it runs approximately 35 feet, and is insulated with 1/2 thick fiberglass insulation.
Read More6/7/2021 · Water Heater / ( $3,800 ) Great running water heater / low pressure steam boiler, was in use indoors at a California Winery in a waste water treatment application that operated only 6 months out of the year. Unit was removed from service and stored indoors in 2008.